Chapter 4 Troubleshooting
Problems Possible cause and remedy
7. Whole screen is ickering or blurring.
Adjust using <Phase>.
8. Characters are blurred. Adjust using <Smoothing>.
9. Upper part of the screen is distorted as shown
below.
This is caused when both composite sync (X-OR)
signal and separate vertical sync signal are input
simultaneously. Select either composite signal or
separate signal.
10. The screen is too bright or too dark. Adjust <Brightness>. (The LCD monitor backlight has a
xed life span. When the screen becomes dark or begins
to icker, contact your local dealer.)
11. Afterimages appear. Use a screen saver or off timer function for a long-time
image display.
Afterimages are particular to LCD monitors. Avoid
displaying the same image for a long time.
12. Green/red/blue/white dots or defective dots remain
on the screen.
This is due to LCD panel characteristics and is not a
failure.
13. Interference patterns or ngerprints remain on the
screen.
Leave the monitor with a white screen. The symptom
may disappear.
14. Noise appears on the screen. Select 1 to 4 in <Signal Filter> from the <Screen> menu
to change the mode.
15. The [Smoothing] icon on the Adjustment menu
[Screen] cannot be selected.
<Smoothing> is disabled with a resolution of 1600 ×
1200 or 800 × 600.
16. The Main menu of Adjustment menu does not start. Check for Adjustment Lock function.
Check whether the FineContrast menu is running. (Refer
to “Simple adjustment [FineContrast mode]” on page 14.)
17. The FineContrast menu does not start. Check whether the Main menu of Adjustment menu is
running. (Refer to “Advanced Adjustments [Adjustment
menu]” on page 15.)
18. The
button does not function. • The button does not function when digital signal is
input.
Check whether the buttons are locked.
19. Frequency does not change after the utility disk is
installed on Windows 98/Me/2000/XP.
Change the input signal frequency using the graphics
board’s utility software.
20. USB function cannot be set up. Check whether the USB cable is connected correctly.
Check whether the PC and OS are USB compliant. (For
USB compliance of the respective devices, consult their
manufacturers.)
Check the PC’s BIOS setting for USB when using
Windows 98/Me/2000/XP. Refer to the manual of the PC
for details.)